Skip to content

Projects

Eight jobs, with the numbers left in.

Every one of these started as a symptom, not a sale. The spec line under each photo is what we actually measured or installed — not marketing copy.

A house at dusk with a heat pump installed
Two-stage heat pump, 1962 ranch

Heat pumpsBelmere

Two-stage heat pump, 1962 ranch

Electric strip heat out, variable-speed heat pump in, and a return duct finally sized for the house it serves.

System
Variable-speed heat pump
On site
2 days
The bonus room that was never comfortable

DuctlessCedar Point

The bonus room that was never comfortable

A single ductless head above the door solved a room that three previous companies had tried to fix with dampers.

System
Single-zone ductless
On site
1 day
Whole-house airflow rebalance

DuctworkRowan Mills

Whole-house airflow rebalance

Static pressure was more than double the equipment spec. New return trunk, two branches resized, dampers set and measured.

Static before
0.98 in. w.c.
After
0.52 in. w.c.
Ceiling diffusers, new build

InstallationKestrel Hill

Ceiling diffusers, new build

Register placement planned with the builder so no supply blows across a ceiling fan or straight at a sofa.

Supplies
14
Returns
3
Dual-fuel changeout before winter

Heating installationWeatherly

Dual-fuel changeout before winter

Heat pump above 35°F, existing gas furnace below it, with the changeover point set from the customer’s own utility rates.

Setup
Dual fuel
On site
1 day
Media filtration without choking the system

Air qualityAshgate

Media filtration without choking the system

A five-inch cabinet sized to the airflow, replacing a one-inch high-MERV filter that was starving the blower.

Filter
5 in. media
Pressure drop
Down 41%
Zoning a split-level that never agreed with itself

ControlsHalstead

Zoning a split-level that never agreed with itself

Two zones, motorized dampers and remote sensors in the rooms people actually sleep in.

Zones
2
Sensors
4
Attic runs, insulated and sealed

DuctworkFenmore

Attic runs, insulated and sealed

Twelve feet of crushed flex replaced with hard pipe, joints mastic-sealed, everything above the insulation line wrapped.

Leakage
Down 62%
On site
1 day

The next write-up on this page could be your house.

Tell us what the system is doing and we will tell you what a visit involves.

Call now(555) 555-0188Request service
Request service